1.
Ann Pharm Fr ; 78(5): 388-397, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32387175

RESUMO

Direct spectrophotometric determination of Maduramicin ammonium (MAD) represents an analytical challenge since it is a weak UV-absorbing and lacking a strong chromophore. This work represents the first spectrophotometric determination of MAD as no direct spectrophotometric or colorimetric determination methods for MAD are available in the literature. The present study illustrates the development of three simple, rapid and inexpensive colorimetric methods for the routine quality control analysis of MAD based on the formation of colored charge transfer complexes with three electron acceptors namely p-chloranilic acid (p-CA), 2,3-dichloro-5,6-dicyano-p-benzoquinone (DDQ) and picric acid (PA). The color products of MAD with p-CA, DDQ and PA were measured at 519, 588 and 405nm respectively. The proposed methods were validated in terms of linearity, ranges, precision, accuracy, robustness and limits of detection and quantification. MAD was effectively determined over concentration ranges of 100-1000, 25-250 and 30-150µg/mL using p-CA, DDQ and PA, respectively with good linearity as shown by the values of correlation coefficients not less than 0.9991. The developed methods were successfully implemented in the assay of MAD powder pharmaceutical formulation for veterinary use.


Assuntos
Lactonas/análise , Compostos de Amônio , Análise Custo-Benefício , Indicadores e Reagentes , Limite de Detecção , Pós , Controle de Qualidade , Reprodutibilidade dos Testes , Espectrofotometria Ultravioleta , Drogas Veterinárias/química , Drogas Veterinárias/normas
2.
Ann Pharm Fr ; 76(1): 16-31, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28842163

RESUMO

This work describes five simple and reliable spectrophotometric and chromatographic methods for analysis of hepatitis C antiviral binary mixture of ledipasvir (LPV) and sofosbuvir (SBV). Method I is based on the use of Amax and derivative spectrophotometry with the zero-crossing technique where LPV was determined using its Amax and 1D amplitudes at 324 and 338nm respectively, while SBV was determined by measuring the 1D amplitudes at 276nm. Method II involves the application of the ratio spectra derivative spectrophotometry. For LPV, 12µg/mL SBV was used as divisor and the 1DD amplitudes at 239.8nm were plotted against LPV concentrations; while by using 10µg/mL LPV, the amplitudes at 279.2nm were found proportional to SBV concentrations. Method III depends on ratio-difference measurement where the peak to trough amplitudes between 229.2 and 268.4nm were measured and correlated to LPV concentration. Similarly, the amplitudes between 268.6 and 229.2nm in the SBV ratio spectra were recorded. For method IV, the two compounds were separated using HPTLC sheets of silica gel and a mobile phase composed of chloroform-methanol (94:6) followed by densitometric measurement of LPV and SBV spots at 331 and 267nm respectively. Method V depends on HPLC-DAD. Effective chromatographic separation was achieved using Thermohypersil C8 column (4.6×250mm, 5µm) with a mobile phase consisting of 0.01M sodium dihydrogen phosphate (pH 2.5) and methanol (20:80) at a flow rate 1.2mL/min and detection at 332 and 262nm for LPV and SBV respectively. Analytical performance of the developed methods was validated according to the ICH guidelines with respect to linearity, ranges, precision, accuracy, detection and quantification limits. The validated methods were successfully applied to the simultaneous analysis of LPV and SBV in mixtures of different proportions and their combined tablet dosage form.


Assuntos
Antivirais/análise , Benzimidazóis/análise , Fluorenos/análise , Hepatite C/tratamento farmacológico , Sofosbuvir/análise , Espectrofotometria Ultravioleta/métodos , Cromatografia Líquida de Alta Pressão , Combinação de Medicamentos , Reprodutibilidade dos Testes , Espectrofotometria Ultravioleta/instrumentação , Comprimidos/análise
3.
Ann Pharm Fr ; 75(3): 176-184, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28187879

RESUMO

A comprehensive stability indicating HPLC with diode array detection method was developed for the determination of the recently approved antiviral drug daclatasvir dihydrochloride (DCV) which is used for the treatment of chronic Hepatitis C Virus (HCV) genotype 3 infection. Effective chromatographic separation was achieved using Waters C8 column (4.6×250mm, 5µm particle size) with isocratic elution of the mobile phase composed of mixed phosphate buffer pH 2.5 and acetonitrile in the ratio of 75:25 (by volume). The mobile phase was pumped at a flow rate of 1.2mL/min, and quantification of DCV was based on measuring its peak areas at 306nm. DCV eluted at retention time 5.4min. Analytical performance of the proposed HPLC procedure was thoroughly validated with respect to system suitability, linearity, range, precision, accuracy, specificity, robustness, detection and quantification limits. The linearity range was 0.6-60µg/mL with correlation coefficient>0.99999. The drug was subjected to forced degradation conditions of neutral, acidic and alkaline hydrolysis, oxidation and thermal degradation. The proposed method proved to be stability-indicating by resolution of the drug from its forced-degradation products. The validated HPLC method was successfully applied to analysis of the cited drug in its tablets.


Assuntos
Antivirais/análise , Hepatite C/tratamento farmacológico , Imidazóis/análise , Carbamatos , Cromatografia Líquida de Alta Pressão , Estabilidade de Medicamentos , Limite de Detecção , Soluções Farmacêuticas , Pirrolidinas , Reprodutibilidade dos Testes , Comprimidos , Valina/análogos & derivados
4.
Ann Pharm Fr ; 74(4): 267-82, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26895689

RESUMO

This work describes five simple and reliable spectrophotometric and chromatographic methods for analysis of the binary mixture of ketorolac tromethamine (KTR) and phenylephrine hydrochloride (PHE). Method I is based on the use of conventional Amax and derivative spectrophotometry with the zero-crossing technique where KTR was determined using its Amax and (1)D amplitudes at 323 and 341nm respectively, while PHE was determined by measuring the (1)D amplitudes at 248.5nm. Method II involves the application of the ratio spectra derivative spectrophotometry. For KTR, 12µg/mL PHE was used as a divisor and the (1)DD amplitudes at 265nm were plotted against KTR concentrations; while - by using 4µg/mL KTR as divisor - the (1)DD amplitudes at 243.5nm were found proportional to PHE concentrations. Method III depends on ratio-difference measurement where the peak to trough amplitudes between 260 and 284nm were measured and correlated to KTR concentration. Similarly, the peak to trough amplitudes between 235 and 260nm in the PHE ratio spectra were recorded. For method IV, the two compounds were separated using Merck HPTLC sheets of silica gel 60 F254 and a mobile phase composed of chloroform/methanol/ammonia (70:30:2, by volume) followed by densitometric measurement of KTR and PHE spots at 320 and 278nm respectively. Method V depends on HPLC-DAD. Effective chromatographic separation was achieved using Zorbax eclipse plus C8 column (4.6×250mm, 5µm) with a mobile phase consisting of 0.05M o-phosphoric acid and acetonitrile (50:50, by volume) at a flow rate 1mL/min and detection at 313 and 274nm for KTR and PHE respectively. Analytical performance of the developed methods was statistically validated according to the ICH guidelines with respect to linearity, ranges, precision, accuracy, detection and quantification limits. The validated spectrophotometric and chromatographic methods were successfully applied to the simultaneous analysis of KTR and PHE in synthetic mixtures of different proportions and laboratory-made ophthalmic solution.


Assuntos
Cetorolaco de Trometamina/análise , Fenilefrina/análise , Cromatografia Líquida de Alta Pressão , Cromatografia em Camada Fina , Limite de Detecção , Padrões de Referência , Reprodutibilidade dos Testes , Espectrofotometria Ultravioleta